Home ProductsTest Sieve Shaker

AT200tap 0~99 Minutes 1~8 Sieves Tap Sieve Shakers for Accurate And Consistent Particle Analysis Testing 278 Oscillations 150 Taps Per Minute

AT200tap 0~99 Minutes 1~8 Sieves Tap Sieve Shakers for Accurate And Consistent Particle Analysis Testing 278 Oscillations 150 Taps Per Minute

AT200tap 0~99 Minutes 1~8 Sieves Tap Sieve Shakers for Accurate And Consistent Particle Analysis Testing 278 Oscillations 150 Taps Per Minute
AT200tap 0~99 Minutes 1~8 Sieves Tap Sieve Shakers for Accurate And Consistent Particle Analysis Testing 278 Oscillations 150 Taps Per Minute
AT200tap 0~99 Minutes 1~8 Sieves Tap Sieve Shakers for Accurate And Consistent Particle Analysis Testing 278 Oscillations 150 Taps Per Minute
Product Details:
Place of Origin: China
Brand Name: AAREAL
Certification: ISO9001:2015
Model Number: AT200tap
Payment & Shipping Terms:
Minimum Order Quantity: 1 Set
Price: Negotiable
Packaging Details: Plywood wooden case for export (fumigation-free)
Delivery Time: 1~30 work days after order confirmed
Payment Terms: T/T, L/C, Western Union, MoneyGram
Supply Ability: 10 sets per month
Contact Now
Detailed Product Description
Main Product: YES Working Mode: Tapping Type Test Sieve Shaker
Digital Display: Included Time Adjustment: 0~99 Minutes
Test Sieve QTY: 1~8 Pcs Material: Carbon Steel For The Frame And Housing
Voltage: Snigle Phase, 220V, 50HZ, Or 220V, 60HZ Colour: White, Stoving Varnish
Sieve Diameter: 200mm, 300mm, 500mm Etc.
Highlight:

rotap sieve shaker

,

test sieve shaker

,

rotap sieve shaker

AT200tap 0~99 Minutes 1~8 Sieves Tap Sieve Shakers for Accurate And Consistent Particle Analysis Testing 278 Oscillations 150 Taps Per Minute

 

 

Overview of Rotap Test Sieve Shaker for Silica Sand Laboratory Particle Size Analysis​:
  AT200tap 0~99 Minutes 1~8 Sieves Tap Sieve Shakers for Accurate And Consistent Particle Analysis Testing 278 Oscillations 150 Taps Per Minute (driven by synchronous belt) made by AAREAL company is in accordance with international products. The working parameters meet the national standards. With test sieve and sample sieve, it can be used for metallurgy, chemical industry, abrasive, super hard materials, feed, food, medicine and other industries screening production and inspection of the powder materials.

  The AT200tap rotap test sieve shaker can be equipped with sound-proof cover or shield according to the requirement.

 

Working Principle of Rotap Test Sieve Shaker for Silica Sand Laboratory Particle Size Analysis​:

  The motor drives the gear speed change through the synchronous belt, making the main shaft rotate. And then the main shaft drives the eccentric wheel to make the slide plate drive the test sieve shake left and right. At the same time, it drives the top gear rotate, strike the hammer and slap the test sieve, making materials in the test sieve and sample sieve screen layer by layer. So people can accurately obtain the materials of multiple particle size ranges at the same time, achieving accurate and rapid screening purposes.

 

Technical Parameters of Rotap Test Sieve Shaker for Silica Sand Laboratory Particle Size Analysis​:

1. This machine is running intermittently. This machine is a intermittent running and 8-hour single-shift operating laboratory equipment.

2. The screen frame of this machine is selected to meet GB/T 6003.1-1997 standard.

3. Motor Power: 0.18KW

4. Number of Revolution: 290±6 times/min

5. Tapping Times: 156±3 times/min

6. Tapping Height: 38±6mm

7. Rotation Distance: 25mm

8. Power Supply: 220V/50HZ or 220V/60HZ

 

NO. Name Value Unit
1 Diameter 300, 200, 150, 100, 75 mm
2 Layer 5~7 Layer
3 Shaking Times 290±10 times/min
4 Tapping Times 156±10 times/min
5 Reciprocating Trip 25 mm
6 Tapping Height 38±6 mm
7 Power 370 W
8 Voltage 380, 220 V
9 Dimensions H700*L460*W420 mm
10 Weight 100 KG
Note: All technical data and dimensions of our products shall be subject to physical objects.
 

Features of Rotap Test Sieve Shaker for Silica Sand Laboratory Particle Size Analysis​:

1. The reproducibility of the test result is good.

2. Simple operation, free of refueling, clean, hygienic and convenient.

3. It can be equipped with 200mm or 205mm sieves, 1~8 layers.

4. Complete synchronous belt conduction power, quick and easy maintenance.

5. Selection of high quality accessories, reasonable structure, low failure rate.

6. Accurate transmission, good consistency.

7. Long life and low maintenance cost.

8. Sound protecting cover can be installed to avoid noise.

9. High screening efficiency.

10. Clean.

 

 

Advantages of Tap Sieve Shaker:
1. High-Efficiency Sieving Mechanism:
Combines horizontal circular motion (278 oscillations/min) and vertical tapping action (150 taps/min) to enhance particle separation efficiency, significantly reducing manual operation time.

 

2. Compatibility & Standardization:
Supports 200mm (8-inch) and 300mm (12-inch) standard sieve stacks, compatible with full/half-height sieves. Complies with international testing standards like ASTM, ideal for certified applications (e.g., foundry sand fineness analysis).

 

3. Durable Industrial Design:
Features a maintenance-free metal frame for heavy-duty use. Some models support auto-adjustment for 110-220V power supply, ensuring global adaptability.

 

4. User-Friendly Operation:
Equipped with touch panels or mechanical controllers, and multi-task displays (e.g., Station 2 remote control) for simplified parameter setup and workflow management .

 

 

Application of Rotap Test Sieve Shaker for Silica Sand Laboratory Particle Size Analysis​:

Our AT200tap rotap test sieve shaker can be used in diamond and other materials of high value, requiring accurate screening of the abrasive industry. This kind of sieve shaker is widely used in metallurgy, powder, chemical, pharmaceutical, building materials, geology, feed, defense and other departments of scientific research and production, laboratory, and quality inspection room, for particle and powdery materials granular structure and sundries amount of standard screening, filtering and inspection sieve test. The device is equipped with timing device to ensure the accuracy and repeatability of the user test results.

 

AT200tap 0~99 Minutes 1~8 Sieves Tap Sieve Shakers for Accurate And Consistent Particle Analysis Testing 278 Oscillations 150 Taps Per Minute 0

 

Contact: Ms. Magie

E-mail: sale@aarealmachine.com

             magiecn@gmail.com

WhatsApp/WeChat: 0086-15637361027

Website: https://www.aarealmachine.com

 

Contact Details
Xinxiang AAREAL Machine Co.,Ltd

Contact Person: Magie

Tel: 86-15637361027

Fax: 86-373-3988367

Send your inquiry directly to us (0 / 3000)

Other Products